Women Health

SUNTRION supports the supply of following mamo machines with eminent service support.

Make : GE medical systems Models: senographe 700t
    DMR
    DMR +
Make : Siemens Models: Nova 1000
    Nova 3000

Specifications of DMR & DMR +

  • Dual Bucky System: Small 18 x 24 and Large 24 x 30
  • Generator: High Frequency X-Ray Generator
  • Tube: Dual Track Molybdenum/Rhodium X-Ray
  • Focal Spots: .01mm and .3mm Focal Spot Sizes
  • Exposure Modes: Three Exposure Modes (Automatic
  • Optimization of Parameters (AOP), Fully Automatic, and AECSemi Automatic/Manual
  • Magnification: 1.3 and 1.9 Magnification Factors – Single Platform
  • Telescopic Motorized Positioning Column: Command Buttons
  • Located on Each Side and Top of the Column for Easy Access
  • Digital Display: Compression Pressure, Breast Thickness, Size
  • of X-Ray Field, and Magnification Factor
  • Foot Pedals: Motorized Compression Controlled by Two
  • Compression/Decompression Foot Pedals with Manual Fine Tunning
  • Compression Paddles: Slide Mount for Stability/Easy of Mounting
  • System Also Includes: Image Receptor, Control Console,
  • Lead/Glass Operator Radiation Shield, Face Guard, Operator
  • Keyboard/Console, DataFlash Patient ID System, Operator
suntrion

MODEL MAMMOMAT 3000 NOVA

Focal spot size, mm (X-RAY TUBE) 0.1 and 0.3
Anode type (X-RAY TUBE) Rotating 8,800 rpm
GENERATOR High-frequency, single- or two-phase power supply
mAs RANGE (X-RAY TUBE) 2-600, Mo tube. The mAs range is 2 with the tube.
Kv range (X-RAY GENERATOR) 23increments of 1 kV
POWER NEEDED 208 VAC, single phase
RADIATION SHIELD (X-RAY TUBE) Yes
Bucky (GENERAL RADIOGRAPHY) optional 18 x 24 cm, 24 x 30 cm; mounted on pivoting arms
ROTATION, ° (ILLUMINATION LEVEL, maximum ft-candles) +135, -180, motorized rotation
Vertical axis, cm (in) (POSITIONING ASSEMBLY) 65-135 (25.6-53.1) motorized
AEC DETECTOR (POSITIONING ASSEMBLY) Solid-state, sandwich design
L x w, cm (in) (CONTROL CONSOLE) 195 x 65 (76.8 x 25.6)
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY) 217 x 52 x 22.5 (85.4 x 20.5 x 9) stand, 196 x 70 x 34 (77 x 27.6 x 13.4) generator

Generator

  • High-voltage wave form: Multipulse
  • Exposure voltage : 23kV to 35kV, adjustable in increments of 1kV
  • mAs range : Mo X-ray tube: 2mAs to 560 mAs (mAs-mode)up to 600mAs (AEC-mode)
  • Mo/W X-ray tube : 2mAs to 710 mAs (mAs-mode) up to 752 mAs (AEC-mode)
  • Exposure times : From 10 ms to 4s , From 10 ms to 7s for magnification techniqueAutomatic exposure control
  • Automatic exposure control (AEC): Microprocessor controlled, transparency compensation
  • Detectors: Semi conductor detector
  • Accuracy of optical density (2-6 cm): ± 0.15 OD from the mean optical density for predefined film screen combinations (separately for each grid table, magnification table and anode-filter combination at appropriate clinical kV).
  • Density correction : ± 3 exposure points, adjustable in 1/8 step increments
  • Film-screen combinations : 2; User selectable on the generator control panel (H/D).
suntrion